Home
About Us
Contact Us
Customer Reviews
Questions? We Can Help
Daikin Ductless Mini Split 19.3 SEER 30,000 BTU
|
![]() |
![]() |
|
![]() |
![]() |
|
|
Daikin Ductless Heat Pump
Performance:
Indoor Unit Model No: FTXS30LVJU
Outdoor Unit Model No: RXS30LVJU
Cooling Capacity (Btu/hr): 30,000
Cooling Capacity (Min-Max): 10,200-30,000
Heating Capacity (Btu/hr): 34,800
Heating Capacity (Min-Max): 10,200-34,800
SEER: 19.3
EER: 10.71
HSPF: 8.3
Power Supply: 60Hz,208/230V,1p
Minimum Circuit Amps: 19.5
Maximum Overcurrent Protection: 20.0 A
Power Consumption – Cooling: 2800W
Power Consumption – Heating: 3900W
Operating Current – Cooling: 12.2A
Operating Current – Heating: 17.1A
Indoor Unit Details:
Moisture Removal (pt/h): 1.5
Airflow Rate (CFM Wet): 706/611/519/473
Airflow Rate (CFM Dry): 710/611/519/469
Sound Pressure – Cooling (H/M/L/SL): 47/45/40/37 dB(A)
Sound Pressure – Heating (H/M/L/SL): 47/44/38/35 dB(A)
Piping Connections:
Liquid (O.D.): Ø 3/8Gas (O.D.): Ø 5/8Condensate Drain (O.D.): Ø 5/8
Dimensions (HxWxD): 13-3/8″ x 47 1/4″ x 9 7/16″
Net Weight (lbs): 38.0
Condensing Unit Details:
Sound Pressure – Cooling (H/M/L/SL): 54/51 dB(A)
Sound Pressure – Heating (H/M/L/SL): 55/51 dB(A)
Operating Range – Cooling: 14-115°F
Operating Range – Cooling with Wind Baffle : 0-115°F
Operating Range – Heating: 5-75°F
Operating Range – Heating with Wind Baffle : 0-75°F
Max Piping Length: 98.4 ft
Max Piping Height: 65.6 ft
Dimensions (HxWxD): 38 15/16 x 37 x12 5/8″
Net Weight (lbs): 179