A word about what your pool guy might say on warranty, installation and other things...
(per Marcus Miller)
When I call a manufacturer they are very motivated to take care of my customer. They will not know who your pool guy is.
You can follow Marcus Miller on Linkedin:
His advice has helped thousands of pool owners in different applications worldwide.
Marc Miller is a Heat Pump expert for geothermal, aquaculture and pool heat pump applications
| Feature | JE1500T | JE2000T | JE2500T | JE2500T3 | JE3000T | JE3000TR | JE3000T3 | JE3000TR3 |
|---|---|---|---|---|---|---|---|---|
| Output* | 72,000 BTUs | 108,000 BTUs | 119,000 BTUs | 119,000 BTUs | 137,000 BTUs | 137,000 BTUs | 137,000 BTUs | 137,000 BTUs |
| Input* | 3.83 kW | 5.03 kW | 5.34 kW | 5.34 kW | 6.37 kW | 6.37 kW | 6.37 kW | 6.37 kW |
| COP | 5.5 | 6.0 | 6.2 | 6.2 | 6.3 | 6.3 | 6.3 | 6.3 |
| Output, Standard Rating Conditions** | 67,000 BTUs | 92,000 BTUs | 106,000 BTUs | 106,000 BTUs | 127,000 BTUs | 127,000 BTUs | 127,000 BTUs | 127,000 BTUs |
| COP, Standard Rating Conditions** | 5.2 | 5.7 | 5.6 | 5.6 | 6.0 | 5.9 | 6.0 | 5.9 |
| Output, Low Ambient** | 46,000 BTUs | 64,000 BTUs | 74,000 BTUs | 74,000 BTUs | 86,000 BTUs | 86,000 BTUs | 86,000 BTUs | 86,000 BTUs |
| C.O.P. Low Ambient** | 4.0 | 4.0 | 4.0 | 4.0 | 4.2 | 4.0 | 4.2 | 4.0 |
| Voltage | 230V / 60Hz | 230V / 60Hz | 230V / 60Hz | 208 / 230V / 60Hz / 3 | 230V / 60Hz | 230V / 60Hz | 208 / 230V / 60Hz / 3 | 208 / 230V / 60Hz / 3 |
| Minimum Circuit Ampacity | 26.14 | 40.21 | 41.81 | 30.76 | 41.81 | 41.81 | 33.00 | 33.00 |
| Max Over Current Protection*** | 45 | 60 | 60 | 45 | 60 | 60 | 50 | 50 |
| LRA | 105 | 178 | 148 | 164 | 185 | 185 | 164 | 164 |
| RLA | 19.87 | 30.77 | 32.05 | 23.21 | 32.05 | 32.05 | 25.00 | 25.00 |
| Compressor | Reciprocating | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll | Scroll |
| Heat Exchanger | Titanium Tube-in-Tube | Titanium High Flow | Titanium High Flow | Titanium High Flow | Titanium High Flow | Titanium High Flow | Titanium High Flow | Titanium High Flow |
| Optimal Water Flow | 30 GPM | 42 GPM | 48 GPM | 48 GPM | 57 GPM | 57 GPM | 57 GPM | 57 GPM |
| Minimum Water Flow | 20 GPM | 20 GPM | 20 GPM | 20 GPM | 20 GPM | 20 GPM | 20 GPM | 20 GPM |
| Maximum Water Flow | 70 GPM | 70 GPM | 70 GPM | 70 GPM | 70 GPM | 70 GPM | 70 GPM | 70 GPM |
| Weight | 175 lbs | 220 lbs | 223 lbs | 223 lbs | 228 lbs | 230 lbs | 228 lbs | 230 lbs |
| Models | Description |
|---|---|
| JE1500T | HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE |
| JE2000T | HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE |
| JE2500T | HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE |
| JE2500T3 | HEAT PUMP ASSEMBLY, 208/230V/60HZ, 3-PHASE, JANDY INTERFACE |
| JE3000T | HEAT PUMP ASSEMBLY, 230V/60HZ, 1-PHASE, JANDY INTERFACE |
| JE3000T3 | HEAT PUMP ASSEMBLY, 208/230V/60HZ, 3-PHASE, JANDY INTERFACE |
| JE3000TR | HEAT PUMP ASSY, REVERSE (HEAT/COOL), 230V/60HZ, 1-PHASE, JANDY INTERFACE |
| JE3000TR3 | HEAT PUMP ASSEMBLY, REVERSE (HEAT/COOL), 208/230V/60HZ, 3-PHASE, JANDY INTERFACE |